| Device Attributes | |||
| Model | Product Type | Description | |
| CR5B0BKP0277 | NE40E-X2-M8A DC | NE40E-X2-M8A Integrated DC Chassis Components | |
| CR5B0BKP0275 | NE40E-X2-M8A AC | NE40E-X2-M8A Integrated AC Chassis Components | |
| 03031EDK | CR5D0MPUK170 | MPUK1 | Main Processing Unit K1 | 
| 03030QDP | CR5D00MPUK70 | MPUK | Main Processing Unit K | 
Technical Specifications
| Typical power consumption | DC:649 W(NPU-240) AC:667 W(NPU-240) DC:1009.2 W(NPU-480) AC:1063.2 W(NPU-480) | 
| Typical heat dissipation | DC:2105.6 BTU/hour(NPU-240) AC:2164 BTU/hour(NPU-240) DC:3274.3 BTU/hour(NPU-480) AC:3449.5 BTU/hour(NPU-480) | 
| DC input voltage | input voltage range: -40V to -72V input rated voltage: -48V/-60V | 
| AC input voltage | input voltage range: 180V to 264V input rated voltage: 200V to 240V/100V to 127V dual live wires | 
| MTBF | 138.61 years | 
| MTTR | 0.5 hours | 
| Availability | 0.999999588 | 
| Slot quantity | 8 | 
| Redundant MPUs | 4.24E-02 | 
| Redundant NPUs | 1:01 | 
| Redundant fans | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. | 
| Redundant power supply | 1+1 | 
| Forwarding performance | 50 Mpps(NPU-50) 180 Mpps(NPU-120) 180 Mpps(NPU-240) 330 Mpps(NPU-480) |